How to read a peptide COA
A COA, or certificate of analysis, is a written test result for one sample. This guide explains how to read a peptide COA line by line: who issued it, what each result means, why purity and quantity are different numbers, and how to check with the lab that a COA is genuine.
Two kinds of COA
A manufacturer's COA is issued by the company that made the batch. It states what the maker measured, and it is the maker's own claim about its own product.
An independent COA is issued by a testing lab with no stake in the product. A seller or a buyer sends the lab a sample, and the lab tests it and writes up what it finds. In a blind test the sample is sent without telling the lab whose product it is.
Both can be useful. Only the second is independent, and a page that calls a manufacturer's COA "third-party tested" is describing it wrongly.
The lines on a COA
| Line | What it tells you | What to check |
|---|---|---|
| Lab | Who did the test | A named lab you can contact |
| Report number | The COA's unique number | That the lab can look it up |
| Verification key | A code for the lab's own copy | That it opens the same COA on the lab's site |
| Sample | What the client said the sample is | The same product and strength as the label |
| Batch or lot | Which production run was tested | The same batch as your pack, where one is given |
| Dates | When the sample arrived and was tested | Recent enough to cover the batch on sale |
| Results | Purity, quantity and identity | Each one, separately (below) |
| Comments | Notes from the lab | Anything about how the sample was tested |
Not every lab issues a verification key; where there is none, the report number and the lab's own records do the same job.
Purity: the share that is the target peptide
Purity is usually measured by HPLC, a liquid chromatography method. The sample is passed through a column, each compound in it comes out at its own time, and each one shows as a peak. Purity is the target peptide's peak as a share of all the peaks: 99% purity means that 99% of what the detector saw was the target peptide, and 1% was something else, such as shorter chains left over from synthesis.
Purity says nothing about how much peptide is in the pack. A pen can be 99% pure and hold more or less than its label says.
Quantity: how much is in the pack
Quantity is the amount of peptide the lab found: in mg for a vial, or in mg/ml for a solution such as a pen. For a pen, multiply by the volume to get the total: a result of 10 mg/ml in a 3 ml pen is 30 mg. Compare that total with the strength on the label.
Our peptide concentration calculator does the conversion between mg, ml and mg/ml.
Identity: is it the right molecule?
Identity is usually confirmed by mass spectrometry, which measures the mass of the molecules in the sample. The result should match the expected molar mass of the peptide on the label: 1,419.5 g/mol for BPC-157, for example, as set out in what is BPC-157.
A purity figure without an identity result can describe a pure sample of the wrong peptide. Identity matters most where one name covers more than one molecule; TB-500 is an example, as TB-500 vs thymosin beta-4 explains.
Blends: one result per component
A blend holds two or more peptides, so its COA should give a result for each one. A single total can hide one component that is low. KLOW, for example, has four components, so a full KLOW COA has four results; our GLOW vs KLOW vs WOLVERINE guide lists the amount of each component on the label.
How to verify a Janoshik COA
Janoshik Analytical calls its report number a task number, and each of its reports carries a verification key.
- Find the task number and the verification key on the COA.
- Open the lab's own copy. On Janoshik's site the address is verify.janoshik.com/tests/ followed by the task number, an underscore and the key.
- Compare every line of the copy you were given with the lab's copy: task number, sample, dates and each result.
- If the lab's copy does not open, or any line differs, treat the COA you were given as not genuine.
Our own report #230680 opens at verify.janoshik.com/tests/230680_HRFJMFMUNFQC, the link printed with it on our lab reports page.
Warning signs
- No report number, or a key that does not open the lab's copy.
- A sample name, strength, batch or date that differs from the lab's copy, or from the product on sale.
- A purity figure with no identity or quantity result.
- A blend COA with one total and no result per component.
- A manufacturer's COA described as independent.
- An image that is cropped, blurred or edited where the numbers are.
Our reports
Our lab reports page writes out every report we hold as text, with its lab, task number, date, results and verification link, so each one can be checked as above.
Sources
- Janoshik Analytical: the task number, verification key and verify.janoshik.com address, as printed on the reports we hold.
- catalogue/products.json: R3vive strengths, volumes and blend components.
All products are supplied for research purposes only.